summaryrefslogtreecommitdiff
path: root/Documentation/ABI/testing/sysfs-class-scsi_host
diff options
context:
space:
mode:
authorAndré Fabian Silva Delgado <emulatorman@parabola.nu>2015-08-05 17:04:01 -0300
committerAndré Fabian Silva Delgado <emulatorman@parabola.nu>2015-08-05 17:04:01 -0300
commit57f0f512b273f60d52568b8c6b77e17f5636edc0 (patch)
tree5e910f0e82173f4ef4f51111366a3f1299037a7b /Documentation/ABI/testing/sysfs-class-scsi_host
Initial import
Diffstat (limited to 'Documentation/ABI/testing/sysfs-class-scsi_host')
-rw-r--r--Documentation/ABI/testing/sysfs-class-scsi_host29
1 files changed, 29 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-scsi_host b/Documentation/ABI/testing/sysfs-class-scsi_host
new file mode 100644
index 000000000..0eb255e7d
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-class-scsi_host
@@ -0,0 +1,29 @@
+What: /sys/class/scsi_host/hostX/isci_id
+Date: June 2011
+Contact: Dave Jiang <dave.jiang@intel.com>
+Description:
+ This file contains the enumerated host ID for the Intel
+ SCU controller. The Intel(R) C600 Series Chipset SATA/SAS
+ Storage Control Unit embeds up to two 4-port controllers in
+ a single PCI device. The controllers are enumerated in order
+ which usually means the lowest number scsi_host corresponds
+ with the first controller, but this association is not
+ guaranteed. The 'isci_id' attribute unambiguously identifies
+ the controller index: '0' for the first controller,
+ '1' for the second.
+
+What: /sys/class/scsi_host/hostX/acciopath_status
+Date: November 2013
+Contact: Stephen M. Cameron <scameron@beardog.cce.hp.com>
+Description: This file contains the current status of the "SSD Smart Path"
+ feature of HP Smart Array RAID controllers using the hpsa
+ driver. SSD Smart Path, when enabled permits the driver to
+ send i/o requests directly to physical devices that are part
+ of a logical drive, bypassing the controllers firmware RAID
+ stack for a performance advantage when possible. A value of
+ '1' indicates the feature is enabled, and the controller may
+ use the direct i/o path to physical devices. A value of zero
+ means the feature is disabled and the controller may not use
+ the direct i/o path to physical devices. This setting is
+ controller wide, affecting all configured logical drives on the
+ controller. This file is readable and writable.