summaryrefslogtreecommitdiff
path: root/Documentation/devicetree/bindings/mfd/da9062.txt
diff options
context:
space:
mode:
authorAndré Fabian Silva Delgado <emulatorman@parabola.nu>2015-12-15 14:52:16 -0300
committerAndré Fabian Silva Delgado <emulatorman@parabola.nu>2015-12-15 14:52:16 -0300
commit8d91c1e411f55d7ea91b1183a2e9f8088fb4d5be (patch)
treee9891aa6c295060d065adffd610c4f49ecf884f3 /Documentation/devicetree/bindings/mfd/da9062.txt
parenta71852147516bc1cb5b0b3cbd13639bfd4022dc8 (diff)
Linux-libre 4.3.2-gnu
Diffstat (limited to 'Documentation/devicetree/bindings/mfd/da9062.txt')
-rw-r--r--Documentation/devicetree/bindings/mfd/da9062.txt88
1 files changed, 88 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/mfd/da9062.txt b/Documentation/devicetree/bindings/mfd/da9062.txt
new file mode 100644
index 000000000..38802b54d
--- /dev/null
+++ b/Documentation/devicetree/bindings/mfd/da9062.txt
@@ -0,0 +1,88 @@
+* Dialog DA9062 Power Management Integrated Circuit (PMIC)
+
+DA9062 consists of a large and varied group of sub-devices:
+
+Device Supply Names Description
+------ ------------ -----------
+da9062-regulator : : LDOs & BUCKs
+da9062-rtc : : Real-Time Clock
+da9062-watchdog : : Watchdog Timer
+
+======
+
+Required properties:
+
+- compatible : Should be "dlg,da9062".
+- reg : Specifies the I2C slave address (this defaults to 0x58 but it can be
+ modified to match the chip's OTP settings).
+- interrupt-parent : Specifies the reference to the interrupt controller for
+ the DA9062.
+- interrupts : IRQ line information.
+- interrupt-controller
+
+See Documentation/devicetree/bindings/interrupt-controller/interrupts.txt for
+further information on IRQ bindings.
+
+Sub-nodes:
+
+- regulators : This node defines the settings for the LDOs and BUCKs. The
+ DA9062 regulators are bound using their names listed below:
+
+ buck1 : BUCK_1
+ buck2 : BUCK_2
+ buck3 : BUCK_3
+ buck4 : BUCK_4
+ ldo1 : LDO_1
+ ldo2 : LDO_2
+ ldo3 : LDO_3
+ ldo4 : LDO_4
+
+ The component follows the standard regulator framework and the bindings
+ details of individual regulator device can be found in:
+ Documentation/devicetree/bindings/regulator/regulator.txt
+
+
+- rtc : This node defines settings required for the Real-Time Clock associated
+ with the DA9062. There are currently no entries in this binding, however
+ compatible = "dlg,da9062-rtc" should be added if a node is created.
+
+- watchdog: This node defines the settings for the watchdog driver associated
+ with the DA9062 PMIC. The compatible = "dlg,da9062-watchdog" should be added
+ if a node is created.
+
+
+Example:
+
+ pmic0: da9062@58 {
+ compatible = "dlg,da9062";
+ reg = <0x58>;
+ interrupt-parent = <&gpio6>;
+ interrupts = <11 IRQ_TYPE_LEVEL_LOW>;
+ interrupt-controller;
+
+ rtc {
+ compatible = "dlg,da9062-rtc";
+ };
+
+ watchdog {
+ compatible = "dlg,da9062-watchdog";
+ };
+
+ regulators {
+ DA9062_BUCK1: buck1 {
+ regulator-name = "BUCK1";
+ regulator-min-microvolt = <300000>;
+ regulator-max-microvolt = <1570000>;
+ regulator-min-microamp = <500000>;
+ regulator-max-microamp = <2000000>;
+ regulator-boot-on;
+ };
+ DA9062_LDO1: ldo1 {
+ regulator-name = "LDO_1";
+ regulator-min-microvolt = <900000>;
+ regulator-max-microvolt = <3600000>;
+ regulator-boot-on;
+ };
+ };
+ };
+