summaryrefslogtreecommitdiff
path: root/Documentation/thermal/exynos_thermal_emulation
diff options
context:
space:
mode:
authorAndré Fabian Silva Delgado <emulatorman@parabola.nu>2015-08-05 17:04:01 -0300
committerAndré Fabian Silva Delgado <emulatorman@parabola.nu>2015-08-05 17:04:01 -0300
commit57f0f512b273f60d52568b8c6b77e17f5636edc0 (patch)
tree5e910f0e82173f4ef4f51111366a3f1299037a7b /Documentation/thermal/exynos_thermal_emulation
Initial import
Diffstat (limited to 'Documentation/thermal/exynos_thermal_emulation')
-rw-r--r--Documentation/thermal/exynos_thermal_emulation53
1 files changed, 53 insertions, 0 deletions
diff --git a/Documentation/thermal/exynos_thermal_emulation b/Documentation/thermal/exynos_thermal_emulation
new file mode 100644
index 000000000..b15efec6c
--- /dev/null
+++ b/Documentation/thermal/exynos_thermal_emulation
@@ -0,0 +1,53 @@
+EXYNOS EMULATION MODE
+========================
+
+Copyright (C) 2012 Samsung Electronics
+
+Written by Jonghwa Lee <jonghwa3.lee@samsung.com>
+
+Description
+-----------
+
+Exynos 4x12 (4212, 4412) and 5 series provide emulation mode for thermal management unit.
+Thermal emulation mode supports software debug for TMU's operation. User can set temperature
+manually with software code and TMU will read current temperature from user value not from
+sensor's value.
+
+Enabling CONFIG_THERMAL_EMULATION option will make this support available.
+When it's enabled, sysfs node will be created as
+/sys/devices/virtual/thermal/thermal_zone'zone id'/emul_temp.
+
+The sysfs node, 'emul_node', will contain value 0 for the initial state. When you input any
+temperature you want to update to sysfs node, it automatically enable emulation mode and
+current temperature will be changed into it.
+(Exynos also supports user changeable delay time which would be used to delay of
+ changing temperature. However, this node only uses same delay of real sensing time, 938us.)
+
+Exynos emulation mode requires synchronous of value changing and enabling. It means when you
+want to update the any value of delay or next temperature, then you have to enable emulation
+mode at the same time. (Or you have to keep the mode enabling.) If you don't, it fails to
+change the value to updated one and just use last succeessful value repeatedly. That's why
+this node gives users the right to change termerpature only. Just one interface makes it more
+simply to use.
+
+Disabling emulation mode only requires writing value 0 to sysfs node.
+
+
+TEMP 120 |
+ |
+ 100 |
+ |
+ 80 |
+ | +-----------
+ 60 | | |
+ | +-------------| |
+ 40 | | | |
+ | | | |
+ 20 | | | +----------
+ | | | | |
+ 0 |______________|_____________|__________|__________|_________
+ A A A A TIME
+ |<----->| |<----->| |<----->| |
+ | 938us | | | | | |
+emulation : 0 50 | 70 | 20 | 0
+current temp : sensor 50 70 20 sensor