@@ -0,0 +1,43 @@
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode
+Date: August 2015
+KernelVersion: 4.2.0
+Contact: source@cogentembedded.com
+Description:
+ Program sensor type for threshold detector inputs.
+ Could be either "GND-Open" or "Supply-Open" mode. Y is a
+ threshold detector input channel. Channels 0..7, 8..15, 16..23
+ and 24..31 has common sensor types.
+
+What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value
+Date: August 2015
+KernelVersion: 4.2.0
+Contact: source@cogentembedded.com
+Description:
+ Channel Y low voltage threshold. If sensor input voltage goes lower then
+ this value then the threshold falling event is pushed.
+ Depending on in_voltageY_sensing_mode the low voltage threshold
+ is separately set for "GND-Open" and "Supply-Open" modes.
+ Channels 0..31 have common low threshold values, but could have different
+ sensing_modes.
+ The low voltage threshold range is between 2..21V.
+ Hysteresis between low and high thresholds can not be lower then 2 and
+ can not be odd.
+ If falling threshold results hysteresis to odd value then rising
+ threshold is automatically subtracted by one.
+
+What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value
+Date: August 2015
+KernelVersion: 4.2.0
+Contact: source@cogentembedded.com
+Description:
+ Channel Y high voltage threshold. If sensor input voltage goes higher then
+ this value then the threshold rising event is pushed.
+ Depending on in_voltageY_sensing_mode the high voltage threshold
+ is separately set for "GND-Open" and "Supply-Open" modes.
+ Channels 0..31 have common high threshold values, but could have different
+ sensing_modes.
+ The high voltage threshold range is between 3..22V.
+ Hysteresis between low and high thresholds can not be lower then 2 and
+ can not be odd.
+ If rising threshold results hysteresis to odd value then falling
+ threshold is automatically appended by one.