diff options
author | Lennart Poettering <lennart@poettering.net> | 2014-02-13 01:35:27 +0100 |
---|---|---|
committer | Lennart Poettering <lennart@poettering.net> | 2014-02-13 01:40:50 +0100 |
commit | d3b1c5083359faa6cfca81810cf87ef70d0290f6 (patch) | |
tree | cfff30a9ffb6cfc83b8a23c39685ef19ba8b3a67 /man/systemd-system.conf.xml | |
parent | 624b5a636f2e0003a67025274d7afe9ebc55423b (diff) |
core: add a system-wide SystemCallArchitectures= setting
This is useful to prohibit execution of non-native processes on systems,
for example 32bit binaries on 64bit systems, this lowering the attack
service on incorrect syscall and ioctl 32→64bit mappings.
Diffstat (limited to 'man/systemd-system.conf.xml')
-rw-r--r-- | man/systemd-system.conf.xml | 121 |
1 files changed, 84 insertions, 37 deletions
diff --git a/man/systemd-system.conf.xml b/man/systemd-system.conf.xml index fd898f75b9..c33e010e36 100644 --- a/man/systemd-system.conf.xml +++ b/man/systemd-system.conf.xml @@ -94,42 +94,6 @@ </varlistentry> <varlistentry> - <term><varname>DefaultTimeoutStartSec=</varname></term> - <term><varname>DefaultTimeoutStopSec=</varname></term> - <term><varname>DefaultRestartSec=</varname></term> - - <listitem><para>Configures the default - time-outs for starting and stopping of - units, as well as the default time to - sleep between automatic restarts of - units, as configured per-unit in - <varname>TimeoutStartSec=</varname>, - <varname>TimeoutStopSec=</varname> and - <varname>RestartSec=</varname> (for - service units, see - <citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry> - for details on the per-unit - settings). For non-service units, - <varname>DefaultTimeoutStartSec=</varname> - sets the default - <varname>TimeoutSec=</varname> value. - </para></listitem> - </varlistentry> - <varlistentry> - <term><varname>DefaultStartLimitInterval=</varname></term> - <term><varname>DefaultStartLimitBurst=</varname></term> - - <listitem><para>Configure the default start rate - limiting, as configured per-service by - <varname>StartLimitInterval=</varname> and - <varname>StartLimitBurst=</varname>. See - <citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry> - for details on the per-service - settings). - </para></listitem> - </varlistentry> - - <varlistentry> <term><varname>CPUAffinity=</varname></term> <listitem><para>Configures the initial @@ -248,6 +212,50 @@ </varlistentry> <varlistentry> + <term><varname>SystemCallArchitectures=</varname></term> + + <listitem><para>Takes a + space-separated list of architecture + identifiers. Selects of which + architectures system calls may be + invoked on this system. This may be + used as an effective way to disable + invocation of non-native binaries + system-wide, for example to prohibit + execution of 32bit x86 binaries on + 64bit x86-64 systems. This option + operates system wide, and acts + similar to the + <varname>SystemCallArchitectures=</varname> + setting of unit files, see + <citerefentry><refentrytitle>systemd.exec</refentrytitle><manvolnum>5</manvolnum></citerefentry> + for details. This setting defaults to + the empty list in which case no + filtering of system calls based on + architecture is applied. Known + architecture identifiers are + <literal>x86</literal>, + <literal>x86-64</literal>, + <literal>x32</literal>, + <literal>arm</literal> and the special + identifier + <literal>native</literal>. The latter + implicitly maps to the native + architecture of the system (or more + specifically, the architecture the + system manager was compiled for). Set + this setting to + <literal>native</literal> to prohibit + execution of any non-native + binaries. When a binary executes a + system call of an architecture that is + not listed in this setting it will be + immediately terminated with the SIGSYS + signal.</para></listitem> + </varlistentry> + + + <varlistentry> <term><varname>TimerSlackNSec=</varname></term> <listitem><para>Sets the timer slack @@ -272,6 +280,42 @@ </varlistentry> <varlistentry> + <term><varname>DefaultTimeoutStartSec=</varname></term> + <term><varname>DefaultTimeoutStopSec=</varname></term> + <term><varname>DefaultRestartSec=</varname></term> + + <listitem><para>Configures the default + time-outs for starting and stopping of + units, as well as the default time to + sleep between automatic restarts of + units, as configured per-unit in + <varname>TimeoutStartSec=</varname>, + <varname>TimeoutStopSec=</varname> and + <varname>RestartSec=</varname> (for + service units, see + <citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry> + for details on the per-unit + settings). For non-service units, + <varname>DefaultTimeoutStartSec=</varname> + sets the default + <varname>TimeoutSec=</varname> value. + </para></listitem> + </varlistentry> + <varlistentry> + <term><varname>DefaultStartLimitInterval=</varname></term> + <term><varname>DefaultStartLimitBurst=</varname></term> + + <listitem><para>Configure the default start rate + limiting, as configured per-service by + <varname>StartLimitInterval=</varname> and + <varname>StartLimitBurst=</varname>. See + <citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry> + for details on the per-service + settings). + </para></listitem> + </varlistentry> + + <varlistentry> <term><varname>DefaultEnvironment=</varname></term> <listitem><para>Sets manager @@ -334,7 +378,10 @@ <para> <citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry>, <citerefentry><refentrytitle>systemd.directives</refentrytitle><manvolnum>7</manvolnum></citerefentry>, - <citerefentry><refentrytitle>environ</refentrytitle><manvolnum>7</manvolnum></citerefentry> + <citerefentry><refentrytitle>systemd.exec</refentrytitle><manvolnum>5</manvolnum></citerefentry>, + <citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry>, + <citerefentry><refentrytitle>environ</refentrytitle><manvolnum>7</manvolnum></citerefentry>, + <citerefentry><refentrytitle>capabilities</refentrytitle><manvolnum>7</manvolnum></citerefentry> </para> </refsect1> |