diff options
author | Lennart Poettering <lennart@poettering.net> | 2017-02-06 13:49:44 +0100 |
---|---|---|
committer | Lennart Poettering <lennart@poettering.net> | 2017-02-06 18:21:27 +0100 |
commit | b3bb64767abacc5b759255a698c89b3495cd54f4 (patch) | |
tree | 2cb580ed47c8ef2542dfedfb08f26fcb6ec06151 /man/systemd.service.xml | |
parent | 3576dddf2768a362f67a0df063c459df05b9c343 (diff) |
man: document that sd_notify() is racy in some cases
Diffstat (limited to 'man/systemd.service.xml')
-rw-r--r-- | man/systemd.service.xml | 40 |
1 files changed, 20 insertions, 20 deletions
diff --git a/man/systemd.service.xml b/man/systemd.service.xml index 522ed5e61e..420ae4e7b5 100644 --- a/man/systemd.service.xml +++ b/man/systemd.service.xml @@ -792,26 +792,26 @@ <varlistentry> <term><varname>NotifyAccess=</varname></term> - <listitem><para>Controls access to the service status - notification socket, as accessible via the - <citerefentry><refentrytitle>sd_notify</refentrytitle><manvolnum>3</manvolnum></citerefentry> - call. Takes one of <option>none</option> (the default), - <option>main</option>, <option>exec</option> or - <option>all</option>. If <option>none</option>, no daemon status - updates are accepted from the service processes, all status - update messages are ignored. If <option>main</option>, only - service updates sent from the main process of the service are - accepted. If <option>exec</option>, only service updates sent - from any of the control processes originating from one of the - <varname>Exec*=</varname> commands are accepted. If - <option>all</option>, all services updates from all members of - the service's control group are accepted. This option should - be set to open access to the notification socket when using - <varname>Type=notify</varname> or - <varname>WatchdogSec=</varname> (see above). If those options - are used but <varname>NotifyAccess=</varname> is not - configured, it will be implicitly set to - <option>main</option>.</para></listitem> + <listitem><para>Controls access to the service status notification socket, as accessible via the + <citerefentry><refentrytitle>sd_notify</refentrytitle><manvolnum>3</manvolnum></citerefentry> call. Takes one + of <option>none</option> (the default), <option>main</option>, <option>exec</option> or + <option>all</option>. If <option>none</option>, no daemon status updates are accepted from the service + processes, all status update messages are ignored. If <option>main</option>, only service updates sent from the + main process of the service are accepted. If <option>exec</option>, only service updates sent from any of the + main or control processes originating from one of the <varname>Exec*=</varname> commands are accepted. If + <option>all</option>, all services updates from all members of the service's control group are accepted. This + option should be set to open access to the notification socket when using <varname>Type=notify</varname> or + <varname>WatchdogSec=</varname> (see above). If those options are used but <varname>NotifyAccess=</varname> is + not configured, it will be implicitly set to <option>main</option>.</para> + + <para>Note that <function>sd_notify()</function> notifications may be attributed to units correctly only if + either the sending process is still around at the time PID 1 processes the message, or if the sending process + is explicitly runtime-tracked by the service manager. The latter is the case if the service manager originally + forked off the process, i.e. on all processes that match <option>main</option> or + <option>exec</option>. Conversely, if an auxiliary process of the unit sends an + <function>sd_notify()</function> message and immediately exits, the service manager might not be able to + properly attribute the message to the unit, and thus will ignore it, even if + <varname>NotifyAccess=</varname><option>all</option> is set for it.</para></listitem> </varlistentry> <varlistentry> |