diff options
author | Lennart Poettering <lennart@poettering.net> | 2012-12-25 16:29:51 +0100 |
---|---|---|
committer | Lennart Poettering <lennart@poettering.net> | 2012-12-31 21:24:26 +0100 |
commit | 240dbaa44f8e5ad51775c776fc3ce9cd2f19f037 (patch) | |
tree | 607e02cd59aef350e3b32698742cd1e00bc71d7c /man | |
parent | 3ec90c030081111900597ec5475d880893f10a76 (diff) |
unit: add ConditionACPower=
Diffstat (limited to 'man')
-rw-r--r-- | man/systemd.unit.xml | 18 |
1 files changed, 18 insertions, 0 deletions
diff --git a/man/systemd.unit.xml b/man/systemd.unit.xml index bf91b4eb13..8570815ad4 100644 --- a/man/systemd.unit.xml +++ b/man/systemd.unit.xml @@ -790,6 +790,7 @@ <term><varname>ConditionSecurity=</varname></term> <term><varname>ConditionCapability=</varname></term> <term><varname>ConditionHost=</varname></term> + <term><varname>ConditionACPower=</varname></term> <term><varname>ConditionNull=</varname></term> <listitem><para>Before starting a unit @@ -959,6 +960,23 @@ The test may be negated by prepending an exclamation mark.</para> + <para><varname>ConditionACPower=</varname> + may may be used to check whether the + system has AC power, or is exlcusively + battery powered at the time of + activation of the unit. This takes a + boolean argument. If set to + <varname>true</varname> the condition + will hold only if at least one AC + connector of the system is connected + to a power source, or if no AC + connectors are known. Conversely, if + set to <varname>false</varname> the + condition will hold only if there is + at least one AC connector known and + all AC connectors are disconnected + from a power source.</para> + <para>Finally, <varname>ConditionNull=</varname> may be used to add a constant condition |