authorLennart Poettering <lennart@poettering.net>2013-06-28 04:12:58 +0200
committerLennart Poettering <lennart@poettering.net>2013-06-28 04:12:58 +0200
commitc2756a68401102786be343712c0c35acbd73d28d (patch)
tree64af93633ce57982937323c9a55fe1ecbf076cd1 /src/core/dbus-manager.c
parent1508e85878cff23a220b2ff8d6c71418e19797de (diff)
core: add transient units
Transient units can be created via the bus API. They are configured via the method call parameters rather than on-disk files. They are subject to normal GC. Transient units currently may only be created for services (however, we will extend this), and currently only ExecStart= and the cgroup parameters can be configured (also to be extended). Transient units require a unique name, that previously had no configuration file on disk. A tool systemd-run is added that makes use of this functionality to run arbitrary command lines as transient services: $ systemd-run /bin/ping www.heise.de Will cause systemd to create a new transient service and run ping in it.
Diffstat (limited to 'src/core/dbus-manager.c')
-rw-r--r--src/core/dbus-manager.c69
1 files changed, 68 insertions, 1 deletions
diff --git a/src/core/dbus-manager.c b/src/core/dbus-manager.c
index c512265903..fe2f749803 100644
--- a/src/core/dbus-manager.c
+++ b/src/core/dbus-manager.c
@@ -239,6 +239,13 @@
" <arg name=\"name\" type=\"s\" direction=\"out\"/>\n" \
" <arg name=\"runtime\" type=\"b\" direction=\"in\"/>\n" \
" <arg name=\"properties\" type=\"a(sv)\" direction=\"in\"/>\n" \
+ " </method>\n" \
+ " <method name=\"StartTransientUnit\">\n" \
+ " <arg name=\"name\" type=\"s\" direction=\"in\"/>\n" \
+ " <arg name=\"mode\" type=\"s\" direction=\"in\"/>\n" \
+ " <arg name=\"properties\" type=\"a(sv)\" direction=\"in\"/>\n" \
+ " <arg name=\"aux\" type=\"a(sa(sv))\" direction=\"in\"/>\n" \
+ " <arg name=\"job\" type=\"o\" direction=\"out\"/>\n" \
" </method>\n"
#define BUS_MANAGER_INTERFACE_SIGNALS \
@@ -1758,7 +1765,7 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection,
SELINUX_UNIT_ACCESS_CHECK(u, connection, message, "start");
- r = bus_unit_set_properties(u, &iter, runtime ? UNIT_RUNTIME : UNIT_PERSISTENT, &error);
+ r = bus_unit_set_properties(u, &iter, runtime ? UNIT_RUNTIME : UNIT_PERSISTENT, true, &error);
if (r < 0)
return bus_send_error_reply(connection, message, &error, r);
@@ -1766,6 +1773,66 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection,
if (!reply)
goto oom;
+ } else if (dbus_message_is_method_call(message, "org.freedesktop.systemd1.Manager", "StartTransientUnit")) {
+ const char *name, *smode;
+ DBusMessageIter iter;
+ JobMode mode;
+ UnitType t;
+ Unit *u;
+
+ if (!dbus_message_iter_init(message, &iter))
+ goto oom;
+
+ if (bus_iter_get_basic_and_next(&iter, DBUS_TYPE_STRING, &name, true) < 0 ||
+ bus_iter_get_basic_and_next(&iter, DBUS_TYPE_STRING, &smode, true) < 0)
+ return bus_send_error_reply(connection, message, NULL, -EINVAL);
+
+ t = unit_name_to_type(name);
+ if (t < 0)
+ return bus_send_error_reply(connection, message, NULL, -EINVAL);
+ if (!unit_vtable[t]->can_transient) {
+ dbus_set_error(&error, DBUS_ERROR_INVALID_ARGS, "Unit type %s does not support transient units.", unit_type_to_string(t));
+ return bus_send_error_reply(connection, message, &error, -EINVAL);
+ }
+
+ mode = job_mode_from_string(smode);
+ if (mode < 0) {
+ dbus_set_error(&error, BUS_ERROR_INVALID_JOB_MODE, "Job mode %s is invalid.", smode);
+ return bus_send_error_reply(connection, message, &error, -EINVAL);
+ }
+
+ r = manager_load_unit(m, name, NULL, NULL, &u);
+ if (r < 0)
+ return bus_send_error_reply(connection, message, &error, r);
+
+ SELINUX_UNIT_ACCESS_CHECK(u, connection, message, "start");
+
+ if (u->load_state != UNIT_NOT_FOUND || set_size(u->dependencies[UNIT_REFERENCED_BY]) > 0) {
+ dbus_set_error(&error, BUS_ERROR_UNIT_EXISTS, "Unit %s already exists.", name);
+ return bus_send_error_reply(connection, message, &error, -EEXIST);
+ }
+
+ /* OK, the unit failed to load and is unreferenced,
+ * now let's fill in the transient data instead */
+ r = unit_make_transient(u);
+ if (r < 0)
+ return bus_send_error_reply(connection, message, &error, r);
+
+ /* Set our properties */
+ r = bus_unit_set_properties(u, &iter, UNIT_RUNTIME, false, &error);
+ if (r < 0)
+ return bus_send_error_reply(connection, message, &error, r);
+
+ /* And load this stub fully */
+ r = unit_load(u);
+ if (r < 0)
+ return bus_send_error_reply(connection, message, &error, r);
+
+ manager_dispatch_load_queue(m);
+
+ /* Finally, start it */
+ return bus_unit_queue_job(connection, message, u, JOB_START, mode, false);
+
} else {
const BusBoundProperties bps[] = {