diff options
author | Lennart Poettering <lennart@poettering.net> | 2010-06-01 19:47:46 +0200 |
---|---|---|
committer | Lennart Poettering <lennart@poettering.net> | 2010-06-01 19:47:46 +0200 |
commit | c87eba546a33ce7ecd66f0e3b61bdf55ae1389f0 (patch) | |
tree | 8309a2b911264e57f95dcb860983e5f8ea506c40 /src/dbus-manager.c | |
parent | f306f4c40d7004be058678ff3ed90c9c006767e0 (diff) |
dbus: add simplified way to start an arbitrary unit in a single method call
Diffstat (limited to 'src/dbus-manager.c')
-rw-r--r-- | src/dbus-manager.c | 79 |
1 files changed, 74 insertions, 5 deletions
diff --git a/src/dbus-manager.c b/src/dbus-manager.c index 6a323019fe..c80b22b9e6 100644 --- a/src/dbus-manager.c +++ b/src/dbus-manager.c @@ -36,6 +36,26 @@ " <arg name=\"name\" type=\"s\" direction=\"in\"/>\n" \ " <arg name=\"unit\" type=\"o\" direction=\"out\"/>\n" \ " </method>\n" \ + " <method name=\"StartUnit\">\n" \ + " <arg name=\"name\" type=\"s\" direction=\"in\"/>\n" \ + " <arg name=\"mode\" type=\"s\" direction=\"in\"/>\n" \ + " <arg name=\"job\" type=\"o\" direction=\"out\"/>\n" \ + " </method>\n" \ + " <method name=\"StopUnit\">\n" \ + " <arg name=\"name\" type=\"s\" direction=\"in\"/>\n" \ + " <arg name=\"mode\" type=\"s\" direction=\"in\"/>\n" \ + " <arg name=\"job\" type=\"o\" direction=\"out\"/>\n" \ + " </method>\n" \ + " <method name=\"ReloadUnit\">\n" \ + " <arg name=\"name\" type=\"s\" direction=\"in\"/>\n" \ + " <arg name=\"mode\" type=\"s\" direction=\"in\"/>\n" \ + " <arg name=\"job\" type=\"o\" direction=\"out\"/>\n" \ + " </method>\n" \ + " <method name=\"RestartUnit\">\n" \ + " <arg name=\"name\" type=\"s\" direction=\"in\"/>\n" \ + " <arg name=\"mode\" type=\"s\" direction=\"in\"/>\n" \ + " <arg name=\"job\" type=\"o\" direction=\"out\"/>\n" \ + " </method>\n" \ " <method name=\"GetJob\">\n" \ " <arg name=\"id\" type=\"u\" direction=\"in\"/>\n" \ " <arg name=\"job\" type=\"o\" direction=\"out\"/>\n" \ @@ -184,6 +204,7 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection DBusError error; DBusMessage *reply = NULL; char * path = NULL; + JobType job_type = _JOB_TYPE_INVALID; assert(connection); assert(message); @@ -248,7 +269,15 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection DBUS_TYPE_INVALID)) goto oom; - } else if (dbus_message_is_method_call(message, "org.freedesktop.systemd1.Manager", "GetJob")) { + } else if (dbus_message_is_method_call(message, "org.freedesktop.systemd1.Manager", "StartUnit")) + job_type = JOB_START; + else if (dbus_message_is_method_call(message, "org.freedesktop.systemd1.Manager", "StopUnit")) + job_type = JOB_STOP; + else if (dbus_message_is_method_call(message, "org.freedesktop.systemd1.Manager", "ReloadUnit")) + job_type = JOB_RELOAD; + else if (dbus_message_is_method_call(message, "org.freedesktop.systemd1.Manager", "RestartUnit")) + job_type = JOB_RESTART; + else if (dbus_message_is_method_call(message, "org.freedesktop.systemd1.Manager", "GetJob")) { uint32_t id; Job *j; @@ -297,7 +326,7 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection HASHMAP_FOREACH_KEY(u, k, m->units, i) { char *u_path, *j_path; - const char *description, *load_state, *active_state, *sub_state, *job_type; + const char *description, *load_state, *active_state, *sub_state, *sjob_type; DBusMessageIter sub2; uint32_t job_id; @@ -323,11 +352,11 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection goto oom; } - job_type = job_type_to_string(u->meta.job->type); + sjob_type = job_type_to_string(u->meta.job->type); } else { job_id = 0; j_path = u_path; - job_type = ""; + sjob_type = ""; } if (!dbus_message_iter_append_basic(&sub2, DBUS_TYPE_STRING, &u->meta.id) || @@ -337,7 +366,7 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection !dbus_message_iter_append_basic(&sub2, DBUS_TYPE_STRING, &sub_state) || !dbus_message_iter_append_basic(&sub2, DBUS_TYPE_OBJECT_PATH, &u_path) || !dbus_message_iter_append_basic(&sub2, DBUS_TYPE_UINT32, &job_id) || - !dbus_message_iter_append_basic(&sub2, DBUS_TYPE_STRING, &job_type) || + !dbus_message_iter_append_basic(&sub2, DBUS_TYPE_STRING, &sjob_type) || !dbus_message_iter_append_basic(&sub2, DBUS_TYPE_OBJECT_PATH, &j_path)) { free(u_path); if (u->meta.job) @@ -636,6 +665,46 @@ static DBusHandlerResult bus_manager_message_handler(DBusConnection *connection } else return bus_default_message_handler(m, message, NULL, properties); + + if (job_type != _JOB_TYPE_INVALID) { + const char *name, *smode; + JobMode mode; + Job *j; + Unit *u; + + if (!dbus_message_get_args( + message, + &error, + DBUS_TYPE_STRING, &name, + DBUS_TYPE_STRING, &smode, + DBUS_TYPE_INVALID)) + return bus_send_error_reply(m, message, &error, -EINVAL); + + if ((mode = job_mode_from_string(smode)) == _JOB_MODE_INVALID) + return bus_send_error_reply(m, message, NULL, -EINVAL); + + if ((r = manager_load_unit(m, name, NULL, &u)) < 0) + return bus_send_error_reply(m, message, NULL, r); + + if (job_type == JOB_START && u->meta.only_by_dependency) + return bus_send_error_reply(m, message, NULL, -EPERM); + + if ((r = manager_add_job(m, job_type, u, mode, true, &j)) < 0) + return bus_send_error_reply(m, message, NULL, r); + + if (!(reply = dbus_message_new_method_return(message))) + goto oom; + + if (!(path = job_dbus_path(j))) + goto oom; + + if (!dbus_message_append_args( + reply, + DBUS_TYPE_OBJECT_PATH, &path, + DBUS_TYPE_INVALID)) + goto oom; + } + free(path); if (reply) { |