diff options
author | Zbigniew Jędrzejewski-Szmek <zbyszek@in.waw.pl> | 2013-03-06 22:15:46 -0500 |
---|---|---|
committer | Zbigniew Jędrzejewski-Szmek <zbyszek@in.waw.pl> | 2013-03-07 00:45:56 -0500 |
commit | aaf080611894aa70af421380af3bca23ad998a8d (patch) | |
tree | 8c5baaf6b9b117ee1a4a3c7f65163c8dff37373d /src/python-systemd | |
parent | 1d98d9a62c16c8282d02942d80e025ceec962c9b (diff) |
systemd-python: catch only ValueErrors in conversion code
First of all, 'try: ... except: ...' (with no exception specified) is
always a no-no, since it catches all BaseExceptions, which includes ^C
and other stuff which should almost never be caught.
Now the conversion is stricter, and only one conversion is attempted,
and only a ValueEror is caught. It seems reasonable to catch ValueErrors,
since the entries in the journal are not verified, and any erroneous
application might log a field which cannot be converted. The consumer
of events must only check if a field is an instance of bytes and can
otherwise assume that the conversion was performed correctly.
Order of arguments in Reader.__init__ has been changed to match order
in _Reader.__init__.
Conversions have been updated to work under Python 2 and 3.
Diffstat (limited to 'src/python-systemd')
-rw-r--r-- | src/python-systemd/journal.py | 98 |
1 files changed, 60 insertions, 38 deletions
diff --git a/src/python-systemd/journal.py b/src/python-systemd/journal.py index 23e1d65747..80299e6b98 100644 --- a/src/python-systemd/journal.py +++ b/src/python-systemd/journal.py @@ -43,13 +43,29 @@ if _sys.version_info >= (3,): else: Monotonic = tuple -_MONOTONIC_CONVERTER = lambda p: Monotonic((_datetime.timedelta(microseconds=p[0]), - _uuid.UUID(bytes=p[1]))) -_REALTIME_CONVERTER = lambda x: _datetime.datetime.fromtimestamp(x / 1E6) +def _convert_monotonic(m): + return Monotonic((_datetime.timedelta(microseconds=m[0]), + _uuid.UUID(bytes=m[1]))) + +def _convert_source_monotonic(s): + return _datetime.timedelta(microseconds=int(s)) + +def _convert_realtime(t): + return _datetime.datetime.fromtimestamp(t / 1E6) + +def _convert_timestamp(s): + return _datetime.datetime.fromtimestamp(int(s) / 1E6) + +if _sys.version_info >= (3,): + def _convert_uuid(s): + return _uuid.UUID(s.decode()) +else: + _convert_uuid = _uuid.UUID + DEFAULT_CONVERTERS = { - 'MESSAGE_ID': _uuid.UUID, - '_MACHINE_ID': _uuid.UUID, - '_BOOT_ID': _uuid.UUID, + 'MESSAGE_ID': _convert_uuid, + '_MACHINE_ID': _convert_uuid, + '_BOOT_ID': _convert_uuid, 'PRIORITY': int, 'LEADER': int, 'SESSION_ID': int, @@ -68,55 +84,60 @@ DEFAULT_CONVERTERS = { 'CODE_LINE': int, 'ERRNO': int, 'EXIT_STATUS': int, - '_SOURCE_REALTIME_TIMESTAMP': _REALTIME_CONVERTER, - '__REALTIME_TIMESTAMP': _REALTIME_CONVERTER, - '_SOURCE_MONOTONIC_TIMESTAMP': _MONOTONIC_CONVERTER, - '__MONOTONIC_TIMESTAMP': _MONOTONIC_CONVERTER, + '_SOURCE_REALTIME_TIMESTAMP': _convert_timestamp, + '__REALTIME_TIMESTAMP': _convert_realtime, + '_SOURCE_MONOTONIC_TIMESTAMP': _convert_source_monotonic, + '__MONOTONIC_TIMESTAMP': _convert_monotonic, 'COREDUMP': bytes, 'COREDUMP_PID': int, 'COREDUMP_UID': int, 'COREDUMP_GID': int, 'COREDUMP_SESSION': int, 'COREDUMP_SIGNAL': int, - 'COREDUMP_TIMESTAMP': _REALTIME_CONVERTER, + 'COREDUMP_TIMESTAMP': _convert_timestamp, } -if _sys.version_info >= (3,): - _convert_unicode = _functools.partial(str, encoding='utf-8') -else: - _convert_unicode = _functools.partial(unicode, encoding='utf-8') - class Reader(_Reader): """Reader allows the access and filtering of systemd journal entries. Note that in order to access the system journal, a non-root user must be in the `adm` group. - Example usage to print out all error or higher level messages - for systemd-udevd for the boot: + Example usage to print out all informational or higher level + messages for systemd-udevd for this boot: - >>> myjournal = journal.Reader() - >>> myjournal.add_boot_match(journal.CURRENT_BOOT) - >>> myjournal.add_loglevel_matches(journal.LOG_ERR) - >>> myjournal.add_match(_SYSTEMD_UNIT="systemd-udevd.service") - >>> for entry in myjournal: + >>> j = journal.Reader() + >>> j.this_boot() + >>> j.log_level(journal.LOG_INFO) + >>> j.add_match(_SYSTEMD_UNIT="systemd-udevd.service") + >>> for entry in j: ... print(entry['MESSAGE']) See systemd.journal-fields(7) for more info on typical fields found in the journal. """ - def __init__(self, converters=None, flags=LOCAL_ONLY, path=None): + def __init__(self, flags=LOCAL_ONLY, path=None, converters=None): """Create an instance of Reader, which allows filtering and return of journal entries. - Argument `converters` is a dictionary which updates the - DEFAULT_CONVERTERS to convert journal field values. + Argument `flags` sets open flags of the journal, which can be one of, or ORed combination of constants: LOCAL_ONLY (default) opens journal on local machine only; RUNTIME_ONLY opens only volatile journal files; and SYSTEM_ONLY opens only journal files of system services and the kernel. + Argument `path` is the directory of journal files. Note that currently flags are ignored when `path` is present as they are currently not relevant. + + Argument `converters` is a dictionary which updates the + DEFAULT_CONVERTERS to convert journal field values. Field + names are used as keys into this dictionary. The values must + be single argument functions, which take a `bytes` object and + return a converted value. When there's no entry for a field + name, then the default UTF-8 decoding will be attempted. If + the conversion fails with a ValueError, unconverted bytes + object will be returned. (Note that ValueEror is a superclass + of UnicodeDecodeError). """ super(Reader, self).__init__(flags, path) if _sys.version_info >= (3,3): @@ -130,18 +151,19 @@ class Reader(_Reader): self.converters.update(converters) def _convert_field(self, key, value): - """Convert value based on callable from self.converters - based of field/key""" + """Convert value using self.converters[key] + + If `key` is not present in self.converters, a standard unicode + decoding will be attempted. If the conversion (either + key-specific or the default one) fails with a ValueError, the + original bytes object will be returned. + """ + convert = self.converters.get(key, bytes.decode) try: - result = self.converters[key](value) - except: - # Default conversion in unicode - try: - result = _convert_unicode(value) - except UnicodeDecodeError: - # Leave in default bytes - result = value - return result + return convert(value) + except ValueError: + # Leave in default bytes + return value def _convert_entry(self, entry): """Convert entire journal entry utilising _covert_field""" @@ -217,7 +239,7 @@ class Reader(_Reader): """ if 0 <= level <= 7: for i in range(level+1): - self.add_match(PRIORITY="%s" % i) + self.add_match(PRIORITY="%d" % i) else: raise ValueError("Log level must be 0 <= level <= 7") |