diff --git a/man/systemd.service.xml b/man/systemd.service.xml
index 20a71afe59..b998a1f81f 100644
--- a/man/systemd.service.xml
+++ b/man/systemd.service.xml
@@ -506,7 +506,8 @@
larger than the configured time, then the service is placed in
a failed state and it will be terminated with
<constant>SIGABRT</constant>. By setting
- <varname>Restart=</varname> to <option>on-failure</option> or
+ <varname>Restart=</varname> to <option>on-failure</option>,
+ <option>on-watchdog</option>, <option>on-abnormal</option> or
<option>always</option>, the service will be automatically
restarted. The time configured here will be passed to the
executed service process in the
@@ -521,7 +522,9 @@
check whether the service manager expects watchdog keep-alive
notifications. See
<citerefentry><refentrytitle>sd_watchdog_enabled</refentrytitle><manvolnum>3</manvolnum></citerefentry>
- for details.
+ for details.
+ <citerefentry><refentrytitle>sd_event_set_watchdog</refentrytitle><manvolnum>3</manvolnum></citerefentry>
+ may be used to enable automatic watchdog notification support.
</para></listitem>
</varlistentry>
@@ -678,8 +681,10 @@
<constant>SIGPIPE</constant>. Exit status definitions can
either be numeric exit codes or termination signal names,
separated by spaces. For example:
- <programlisting>SuccessExitStatus=1 2 8
- SIGKILL</programlisting> ensures that exit codes 1, 2, 8 and
+
+ <programlisting>SuccessExitStatus=1 2 8 SIGKILL</programlisting>
+
+ ensures that exit codes 1, 2, 8 and
the termination signal <constant>SIGKILL</constant> are
considered clean service terminations.
</para>
@@ -711,14 +716,16 @@
signal names, and are separated by spaces. Defaults to the
empty list, so that, by default, no exit status is excluded
from the configured restart logic. For example:
- <programlisting>RestartPreventExitStatus=1 6
- SIGABRT</programlisting> ensures that exit codes 1 and 6 and
- the termination signal <constant>SIGABRT</constant> will not
- result in automatic service restarting. This option may appear
- more than once, in which case the list of restart-preventing
- statuses is merged. If the empty string is assigned to this
- option, the list is reset and all prior assignments of this
- option will have no effect.</para></listitem>
+
+ <programlisting>RestartPreventExitStatus=1 6 SIGABRT</programlisting>
+
+ ensures that exit codes 1 and 6 and the termination signal
+ <constant>SIGABRT</constant> will not result in automatic
+ service restarting. This option may appear more than once, in
+ which case the list of restart-preventing statuses is
+ merged. If the empty string is assigned to this option, the
+ list is reset and all prior assignments of this option will
+ have no effect.</para></listitem>
</varlistentry>