summaryrefslogtreecommitdiff
path: root/udevtrigger.xml
diff options
context:
space:
mode:
Diffstat (limited to 'udevtrigger.xml')
-rw-r--r--udevtrigger.xml129
1 files changed, 0 insertions, 129 deletions
diff --git a/udevtrigger.xml b/udevtrigger.xml
deleted file mode 100644
index eb2b9851cd..0000000000
--- a/udevtrigger.xml
+++ /dev/null
@@ -1,129 +0,0 @@
-<?xml version='1.0'?>
-<!DOCTYPE article PUBLIC "-//OASIS//DTD DocBook XML V4.2//EN"
- "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">
-
-<article>
- <section>
- <title>udevtrigger</title>
- <refentry>
- <refentryinfo>
- <title>udevtrigger</title>
- <date>March 2006</date>
- <productname>udev</productname>
- </refentryinfo>
-
- <refmeta>
- <refentrytitle>udevtrigger</refentrytitle>
- <manvolnum>8</manvolnum>
- <refmiscinfo class="version"></refmiscinfo>
- </refmeta>
-
- <refnamediv>
- <refname>udevtrigger</refname><refpurpose>request kernel devices events for coldplug</refpurpose>
- </refnamediv>
-
- <refsynopsisdiv>
- <cmdsynopsis>
- <command>udevtrigger</command>
- <arg><option>--verbose</option></arg>
- <arg><option>--dry-run</option></arg>
- <arg><option>--retry-failed</option></arg>
- <arg><option>--help</option></arg>
- <arg><option>--action=<replaceable>action</replaceable></option></arg>
- <arg><option>--subsystem-match=<replaceable>subsystem</replaceable></option></arg>
- <arg><option>--subsystem-nomatch=<replaceable>subsystem</replaceable></option></arg>
- <arg><option>--attr-match=<replaceable>attribute=value</replaceable></option></arg>
- <arg><option>--attr-nomatch=<replaceable>attribute=value</replaceable></option></arg>
- </cmdsynopsis>
- </refsynopsisdiv>
-
- <refsect1><title>DESCRIPTION</title>
- <para>Trigger kernel device uevents to replay missing events at system coldplug.</para>
- </refsect1>
-
- <refsect1><title>OPTIONS</title>
- <variablelist>
- <varlistentry>
- <term><option>--verbose</option></term>
- <listitem>
- <para>Print the list of devices which will be triggered.</para>
- </listitem>
- </varlistentry>
- <varlistentry>
- <term><option>--dry-run</option></term>
- <listitem>
- <para>Do not actually trigger the event.</para>
- </listitem>
- </varlistentry>
- <varlistentry>
- <term><option>--retry-failed</option></term>
- <listitem>
- <para>Trigger only the events which are failed during a previous run.</para>
- </listitem>
- </varlistentry>
- <varlistentry>
- <term><option>--action=<replaceable>action</replaceable></option></term>
- <listitem>
- <para>Type of event to be triggered. The default value is "add".</para>
- </listitem>
- </varlistentry>
- <varlistentry>
- <term><option>--subsystem-match=<replaceable>subsystem</replaceable></option></term>
- <listitem>
- <para>Trigger events for devices which belong to a matching subsystem. This option
- can be specified multiple times and supports shell style pattern matching.</para>
- </listitem>
- </varlistentry>
- <varlistentry>
- <term><option>--subsystem-nomatch=<replaceable>subsystem</replaceable></option></term>
- <listitem>
- <para>Do not trigger events for devices which belong to a matching subsystem. This option
- can be specified multiple times and supports shell style pattern matching.</para>
- </listitem>
- </varlistentry>
- <varlistentry>
- <term><option>--attr-match=<replaceable>attribute=value</replaceable></option></term>
- <listitem>
- <para>Trigger events for devices with a matching sysfs attribute. If a value is specified
- along with the attribute name, the content of the attribute is matched against the given
- value using shell style pattern matching. If no value is specified, the existence of the
- sysfs attribute is checked. This option can be specified multiple times.</para>
- </listitem>
- </varlistentry>
- <varlistentry>
- <term><option>--attr-nomatch<replaceable>attribute=value</replaceable></option></term>
- <listitem>
- <para>Do not trigger events for devices with a matching sysfs attribute. If a value is
- specified along with the attribute name, the content of the attribute is matched against
- the given value using shell style pattern matching. If no value is specified, the existence
- of the sysfs attribute is checked. This option can be specified multiple times.</para>
- </listitem>
- </varlistentry>
- </variablelist>
- </refsect1>
-
- <refsect1><title>ENVIRONMENT</title>
- <variablelist>
- <varlistentry>
- <term><option>UDEV_LOG</option></term>
- <listitem>
- <para>Overrides the syslog priority specified in the config file.</para>
- </listitem>
- </varlistentry>
- </variablelist>
- </refsect1>
-
- <refsect1><title>AUTHOR</title>
- <para>Written by Kay Sievers <email>kay.sievers@vrfy.org</email> and
- Hannes Reinecke <email>hare@suse.de</email>.</para>
- </refsect1>
-
- <refsect1>
- <title>SEE ALSO</title>
- <para><citerefentry>
- <refentrytitle>udev</refentrytitle><manvolnum>7</manvolnum>
- </citerefentry></para>
- </refsect1>
- </refentry>
- </section>
-</article>