Age | Commit message (Collapse) | Author |
|
Add -r/--reverse option to coredumpctl
|
|
test-execute without capsh
|
|
Extended evdev keyboard match rule + cube iwork8 air keymap fixup hwdb entry
|
|
Like journalctl, users sometimes want to see coredump list in reverse
order.
Signed-off-by: Namhyung Kim <namhyung@gmail.com>
|
|
It seems the -o opiton and -D option can be printed together.
Signed-off-by: Namhyung Kim <namhyung@gmail.com>
|
|
Silence gcc warnings
|
|
|
|
the one we are compiled for (#5272)
It's a difference. Not a big one, but let's be correct here.
|
|
|
|
a good number of resolved fixes
|
|
src/core/dbus.c: In function 'find_unit':
src/core/dbus.c:334:15: warning: 'u' may be used uninitialized in this function [-Wmaybe-uninitialized]
*unit = u;
^
src/core/dbus.c:301:15: note: 'u' was declared here
Unit *u;
^
|
|
At -O3, this was printed a hundred times for various callers of
manager_add_job_by_name(). AFAICT, there is no error and `unit` is always
intialized. Nevertheless, add explicit initialization to silence the noise.
src/core/manager.c: In function 'manager_start_target':
src/core/manager.c:1413:16: warning: 'unit' may be used uninitialized in this function [-Wmaybe-uninitialized]
return manager_add_job(m, type, unit, mode, e, ret);
^
src/core/manager.c:1401:15: note: 'unit' was declared here
Unit *unit;
^
|
|
We were inconsistent, manager_load_unit_prepare() would crash if _ret was ever NULL.
But none of the callers use NULL. So simplify things and require it to be non-NULL.
|
|
The home and power buttons on the Cube iwork8 air tablet are swapped,
add a hwdb entry fixing this up.
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
|
|
Sometimes a system may have 2 input event nodes with the same name where
we only want to apply keyboard hwdb rules to 1 of the 2 devices.
This problem happens e.g. on devices where the soc_button_array driver is
used (e.g. intel atom based tablets) which registers 2 event nodes with
the name "gpio-keys".
This commit adds a new extended match rule which extends the match to also
check $attr{phys} and $attr{capabilities/ev}, allowing to differentiate
between devices with an identical name.
Suggested-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
|
|
PermissionsStartOnly= (#5309)
ReadOnlyPaths=, ProtectHome=, InaccessiblePaths= and ProtectSystem= are
about restricting access and little more, hence they should be disabled
if PermissionsStartOnly= is used or ExecStart= lines are prefixed with a
"+". Do that.
(Note that we will still create namespaces and stuff, since that's about
a lot more than just permissions. We'll simply disable the effect of
the four options mentioned above, but nothing else mount related.)
This also adds a test for this, to ensure this works as intended.
No documentation updates, as the documentation are already vague enough
to support the new behaviour ("If true, the permission-related execution
options…"). We could clarify this further, but I think we might want to
extend the switches' behaviour a bit more in future, hence leave it at
this for now.
Fixes: #5308
|
|
a2eb5ea79c added a new field to `CalendarComponent`; update
`normalize_chain` to compare all fields when dropping duplicates
|
|
Fixes:
```
src/shared/bus-unit-util.c: In function ‘bus_append_unit_property_assignment’:
src/shared/bus-unit-util.c:570:65: warning: passing argument 2 of ‘namespace_flag_from_string_many’ from incompatible pointer type [-Wincompatible-pointer-types]
r = namespace_flag_from_string_many(eq, &flags);
^
In file included from src/shared/bus-unit-util.c:31:0:
src/shared/nsflags.h:41:5: note: expected ‘long unsigned int *’ but argument is of type ‘uint64_t * {aka long long unsigned int *}’
int namespace_flag_from_string_many(const char *name, unsigned long *ret);
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
```
Closes #5312
|
|
Closes #5313
|
|
a small number of install and unit management related fixes
|
|
|
|
#4067 added documentation to systemd.exec(5), but not systemd.journal-fields(7).
|
|
|
|
|
|
Fixes #5273.
|
|
replace test/sys.tar.xz with script to create test/sys/ contents
|
|
IPv6 Neighbor discovery proxy is the IPv6 equivalent to proxy ARP for IPv4.
It is required when ISPs do not unconditional route IPv6 subnets
to their designated target, but expect neighbor solicitation messages
for every address on a link.
A variable IPv6ProxyNDPAddress= is introduced to the [Network] section,
each representing a IPv6 neighbour proxy entry in the neighbour table.
|
|
https://lists.freedesktop.org/archives/systemd-devel/2017-February/038286.html
Let's keep both the old and new for now, so systemd builds correctly in either
environment. Later on we should drop the old.
|
|
this way, we can still call seccomp ourselves, even if seccomp() is
blocked by the filter we are installing.
Fixes: #5300
|
|
The tarball is no longer needed, as the sys-script.py script creates
all the sys/ contents.
|
|
|
|
The script contains the contents of all sys/ test files, and creates
all dirs/links/files when run. This replaces the sys.tar.xz tarball
that contained sys/, so changes to sys files only require a simple
commit in git, instead of checking in an entire new tarball for each
sys/ change.
|
|
Instead of keeping all sys/ nodes in a tarball, use a script
"sys-script.py" to create all the sys/ entries.
This adds a script to create that initial "sys-script.py" script, using
an existing sys/ directory, created from the sys.tar.xz contents.
The "sys-script.py" can then be edited or recreated later, when any sys/
files are added or modified; the change will be only a patch to the
"sys-script.py" script in git, instead of forcing git to store a new
binary tarball.
|
|
So far, if either $HOME or $XDG_RUNTIME_DIR is not set we wouldn't use
either, and fail acquire_config_dirs() and acquire_control_dirs() in
their entireties. With this change, let's make use of the variables we
can acquire, and don't bother with the other.
Specifically this means: in both acquire_config_dirs() and
acquire_control_dirs() handle ENXIO from user_config_dir() and
user_runtime_dir() directly, instead of propagating it up and handling
it in the caller.
|
|
If the strv is empty, then strv_extend_strv_concat() is a NOP anyway,
and hence there is no reason to guard for this explicitly.
|
|
Let's use get_home_dir() for figuring out the home directory, so that
there's a good chance we succeed figuring out unit locations even if
$HOME isn't set.
Fixes: #5260
|
|
configuration symlinks
Under specific circumstances it might happen that we can't figure out
where to place our symlinks, for example because we are supposed to
create them in the runtime directory but $XDG_RUNTIME_DIR is not set. In
this case, return -ENXIO instead of hitting an assert().
(Yeah, the error isn't very descriptive, but for now this should at
least be good enough to remove the assert() being hit.)
|
|
In some cases there might be unit symlinks in .wants/ or .requires/
directories even though the unit is otherwise fully removed. In this
case, don't fail removal, but still remove the symlinks.
This reworks the symlink marking logic to always add unit files that we
are missing to the changes list, but proceed with any symlink removal
for them. This way we'll still generate useful hints that a unit is
missing if you invoke "systemctl disable idontexist.service", but also
still remove any link to it.
Fixes: #4995
|
|
We protect less interetsing stuff with selinux "status", let's do that
here too.
|
|
off the bus (#5294)
Fixes: #4528
|
|
In networkd-test.py, show resolved's journal on failure, to debug issues
like https://github.com/systemd/systemd/pull/5283.
|
|
We added mmap() and mmap2(), but forgot munmap(). Fix that.
Pointed out by @lucaswerkmeister:
https://github.com/systemd/systemd/pull/4537#issuecomment-273275298
|
|
Two doc fixes
|
|
Shut up canonicalize debug log messages
|
|
Previously, we'd refuse the GetUnitProcesses() bus call if the unit file
couldn't be loaded. Which is wrong, as admins should be able to inspect
services whose unit files was deleted. Change this logic, so that we
permit introspecting the processes of any unit that is loaded,
regardless if it has a unit file or not.
(Note that we won't load unit files in GetUnitProcess(), but only
operate on already loaded ones. That's because only loaded units can
have processes — as that's how our GC logic works — and hence loading
the unit just for the process tree is pointless, as it would be empty).
See: #4995
|
|
Just as a matter of coding style: whenever we return successfully, let's
make sure all our return parameters are properly initialized to
something.
|
|
After generating the template name we can shortcut things and just call
unit_file_find_dirs() from inside itself, just with the new name and
save a good number of duplicate lines.
|
|
|
|
After all, most units won't have drop-in dirs, hence there's no point in
logging about that.
Fixes: #5252
|
|
This builds on @utezduyar's #4640, but extends on it.
Fixes: #4550
Replaces: #4640
|