summaryrefslogtreecommitdiff
AgeCommit message (Collapse)Author
2014-06-11tmpfiles: always recreate the most basic directory structure in /varLennart Poettering
Let's allow booting up with /var empty. Only create the most basic directories to get to a working directory structure and symlink set in /var.
2014-06-11update TODOLennart Poettering
2014-06-10tmpfiles: get rid of "m" lines, make them redundant by "z"Lennart Poettering
"m" so far has been a non-globbing version of "z". Since this makes it quite redundant, let's get rid of it. Remove "m" from the man pages, beef up "z" docs instead, and make "m" nothing more than a compatibility alias for "z".
2014-06-10tmpfiles: add new "C" line for copying files or directoriesLennart Poettering
2014-06-10tmpfiles: various modernizationsLennart Poettering
2014-06-10label: when clearing selinux context, don't mangle errnoLennart Poettering
2014-06-10bus-proxy: fix misplaced s/system/session/Mantas Mikulėnas
2014-06-10machine-id-setup: fix array size of parametersLennart Poettering
Not that it really would have any effect on the generated code, but let's not confuse people...
2014-06-10log: honour the kernel's quiet cmdline argumentRonny Chevalier
It was forgotten in b1e90ec515408aec2702522f6f68c4920b56375b See https://bugs.freedesktop.org/show_bug.cgi?id=79582
2014-06-10udev: check the return value from udev_enumerate_scan_devicesThomas Hindoe Paaboel Andersen
The return value from udev_enumerate_scan_devices was stored but never used. I assume this was meant to be checked.
2014-06-10tests: do not use systemctl status --failedRonny Chevalier
since v212 calling systemctl status without arguments will show a overall system state
2014-06-10backlight: Do not clamp brightness for LEDsDenis Tikhomirov
https://bugs.freedesktop.org/show_bug.cgi?id=77092 On Thu, Jun 05, 2014 at 08:37:20AM +0200, Lennart Poettering wrote: > The patch is line-broken, please send an uncorrupted patch! I am very sorry, I forgot that my client limits line width. I will use mutt now on. > clamp_brightness() clamps the brightness value to the range of the > actual device. This is a recent addition that was added to deal with > driver updates where the resolution is changed. I don't think this part > should be dropped for LED devices. The clamp_brightness() call hence > should be called unconditionally, however, internally it should use a > different min_brightness value if something is an !backlight devices... Thank you for explanation, this sounds very reasonable to me. Please, see updated patch:
2014-06-10man: updates to the passive target sectionLennart Poettering
2014-06-10systemd-detect-virt: only discover Xen domUThomas Blume
The current vm detection lacks the distinction between Xen dom0 and Xen domU. Both, dom0 and domU are running inside the hypervisor. Therefore systemd-detect-virt and the ConditionVirtualization directive detect dom0 as a virtual machine. dom0 is not using virtual devices but is accessing the real hardware. Therefore dom0 should be considered the virtualisation host and not a virtual machine. https://bugs.freedesktop.org/show_bug.cgi?id=77271
2014-06-10man: Searching for an explanation of what a "slice unit" was, found this, ↵Mark Eichin
felt compelled to send in fixes for the obvious typos
2014-06-10bus-proxy: properly index policy by uid/gid when parsingLennart Poettering
2014-06-10bus-proxy: read the right policy when running in user modeLennart Poettering
2014-06-10udev: really exclude device-mapper from block device ownership event lockingChristian Hesse
Arguments were wrong order, no? This fixes commits: e918a1b5a94f270186dca59156354acd2a596494 3d06f4183470d42361303086ed9dedd29c0ffc1b
2014-06-09man: clarify the effect of replace-irreversibly on future conflicting jobsDavid Strauss
2014-06-09build: fix copypaste error in networkd-wait-online symlinkDave Reisner
2014-06-08bus-policy.c: use draw_special_char(DRAW_ARROW)Daniel Buch
Lets allow LC_ALL=C without corrupted output
2014-06-07Fix spelling mistake, proces -> processColin Ian King
2014-06-07nspawn: split long message into two linesZbigniew Jędrzejewski-Szmek
For names like /var/lib/container/something, the message becomes quite long. Better to split it. Also reword the message not to suggest that ^]^]^] only works in the beginning.
2014-06-07bus-proxyd: do not free NULL itemsKay Sievers
2014-06-07Remove sysv parser from service.cThomas Hindoe Paaboel Andersen
Parsing sysv files was moved to the sysv-generator in the previous commit. This patch removes the sysv parsing from serivce.c. Note that this patch drops the following now unused sysv-specific info from service dump: "SysV Init Script has LSB Header: (yes/no)" "SysVEnabled: (yes/no)" "SysVRunLevels: (levels)"
2014-06-07Move handling of sysv initscripts to a generatorThomas Hindoe Paaboel Andersen
Reuses logic from service.c and the rc-local generator. Note that this drops reading of chkconfig entirely. It also drops reading runlevels from the LSB headers. The runlevels were only used to check for runlevels outside of the normal 1-5 range and then add special dependencies and settings. Special runlevels were dropped in the past so it seemed to be unused code. The generator does not know about non-generated units with a value set with SysVStartPriority=. These are therefor not taken into account when converting start priority to before/after.
2014-06-07core: allow transient mount unitsTom Gundersen
For now only What=, Options=, Type= are supported, and Where= is deduced from the unit name.
2014-06-06fix warningsThomas Hindoe Paaboel Andersen
Prevent use of uninitialized variable and removed a now unused cleanup function for freeaddrinfo
2014-06-06bus-proxy: properly read user/group policy itemsLennart Poettering
2014-06-06bus: add basic dbus1 policy parserLennart Poettering
Enforcement is still missing, but at least we can parse it now.
2014-06-06update TODOLennart Poettering
2014-06-06sd-bus: don't allow creating message objects that are not attached to a busLennart Poettering
It seems unnecessary to support this, and we rather should avoid allowing this at all, so that people don't program against this sloppily and we end up remarshalling all the time...
2014-06-06units: pull in time-sync.target from systemd-timedated.serviceLennart Poettering
After all, that's what we document for time-sync.target in systemd.special(5), hence let's follow our own suggestion.
2014-06-06man: fix references to sd_journal_cutoff_realtime_usecMantas Mikulėnas
2014-06-06update TODOLennart Poettering
2014-06-06namespace: cover /boot with ProtectSystem= againLennart Poettering
Now that we properly exclude autofs mounts from ProtectSystem= we can include it in the effect of ProtectSystem= again.
2014-06-06units: fix minor typoLennart Poettering
2014-06-06namespace: beef up read-only bind mount logicLennart Poettering
Instead of blindly creating another bind mount for read-only mounts, check if there's already one we can use, and if so, use it. Also, recursively mark all submounts read-only too. Also, ignore autofs mounts when remounting read-only unless they are already triggered.
2014-06-05namespace: also include /root in ProtectHome=Lennart Poettering
/root can't really be autofs, and is also a home, directory, so cover it with ProtectHome=.
2014-06-05namespace: when setting up an inaccessible mount point, unmounting ↵Lennart Poettering
everything below This has the benefit of not triggering any autofs mount points unnecessarily.
2014-06-05umount: modernizationsLennart Poettering
2014-06-05util: fix fd_cloexec(), fd_nonblock()Lennart Poettering
2014-06-05core: introduce new Restart=on-abnormal settingLennart Poettering
Restart=on-abnormal is similar to Restart=on-failure, but avoids restarts on unclean exit codes (but still doing restarts on all obviously unclean exits, such as timeouts, signals, coredumps, watchdog timeouts). Also see: https://fedorahosted.org/fpc/ticket/191
2014-06-05update TODOLennart Poettering
2014-06-05sd-daemon: introduce sd_pid_notify() and sd_pid_notifyf()Lennart Poettering
sd_pid_notify() operates like sd_notify(), however operates on a different PID (for example the parent PID of a process). Make use of this in systemd-notify, so that message are sent from the PID specified with --pid= rather than the usually shortlived PID of systemd-notify itself. This should increase the likelyhood that PID 1 can identify the cgroup that the notification message was sent from properly.
2014-06-05update TODOLennart Poettering
2014-06-05socket-proxyd: port to asynchronous name resolution using sd-resolveLennart Poettering
2014-06-05update TODOLennart Poettering
2014-06-05bus: make use of sd_bus_try_close() in exit-on-idle servicesLennart Poettering
2014-06-05sd-event: restore correct timeout behaviourLennart Poettering