Age | Commit message (Collapse) | Author |
|
This is primarily useful for services that need to track clients which
reference certain objects they maintain, or which explicitly want to
subscribe to certain events. Something like this is done in a large
number of services, and not trivial to do. Hence, let's unify this at
one place.
This also ports over PID 1 to use this to ensure that subscriptions to
job and manager events are correctly tracked. As a side-effect this
makes sure we properly serialize and restore the track list across
daemon reexec/reload, which didn't work correctly before.
This also simplifies how we distribute messages to broadcast to the
direct busses: we only track subscriptions for the API bus and
implicitly assume that all direct busses are subscribed. This should be
a pretty OK simplification since clients connected via direct bus
connections are shortlived anyway.
|
|
SipHash appears to be the new gold standard for hashing smaller strings
for hashtables these days, so let's make use of it.
|
|
|
|
Message handler callbacks can be simplified drastically if the
dispatcher automatically replies to method calls if errors are returned.
Thus: add an sd_bus_error argument to all message handlers. When we
dispatch a message handler and it returns negative or a set sd_bus_error
we send this as message error back to the client. This means errors
returned by handlers by default are given back to clients instead of
rippling all the way up to the event loop, which is desirable to make
things robust.
As a side-effect we can now easily turn the SELinux checks into normal
function calls, since the method call dispatcher will generate the right
error replies automatically now.
Also, make sure we always pass the error structure to all property and
method handlers as last argument to follow the usual style of passing
variables for return values as last argument.
|
|
This patch converts PID 1 to libsystemd-bus and thus drops the
dependency on libdbus. The only remaining code using libdbus is a test
case that validates our bus marshalling against libdbus' marshalling,
and this dependency can be turned off.
This patch also adds a couple of things to libsystem-bus, that are
necessary to make the port work:
- Synthesizing of "Disconnected" messages when bus connections are
severed.
- Support for attaching multiple vtables for the same interface on the
same path.
This patch also fixes the SetDefaultTarget() and GetDefaultTarget() bus
calls which used an inappropriate signature.
As a side effect we will now generate PropertiesChanged messages which
carry property contents, rather than just invalidation information.
|