Age | Commit message (Collapse) | Author |
|
If there's no remaining process to kill, skip the SIGKILL states if
SIGKILL is disabled.
Effectively this doesn't change much since if there's nothing to kill
with SIGTERM or SIGABRT then there's also nothing to kill with SIGKILL.
However, this avoids confusion with the state engine jumping through
SIGKILL states for no reason...
|
|
|
|
|
|
|
|
|
|
|
|
|
|
disabled
|
|
|
|
Because the order of coldplugging is not defined, we can reference a
not-yet-coldplugged unit and read its state while it has not yet been
set to a meaningful value.
This way, already active units may get started again.
We fix this by deferring such actions until all units have been at
least somehow coldplugged.
Fixes https://bugs.freedesktop.org/show_bug.cgi?id=88401
|
|
This adds support for showing the accumulated consumed CPU time per-unit
in the "systemctl status" output. The property is also readable via the
bus.
|
|
This patch removes includes that are not used. The removals were found with
include-what-you-use which checks if any of the symbols from a header is
in use.
|
|
After all it is now much more like strjoin() than strappend(). At the
same time, add support for NULL sentinels, even if they are normally not
necessary.
|
|
changing unit state
Unit _start() and _stop() implementations can fail with -EAGAIN to delay
execution temporarily. Thus, we should not output status messages before
invoking these calls, but after, and only when we know that the
invocation actually made a change.
|
|
.busname units, if BusName= is set
|
|
|
|
With this change it is possible to send file descriptors to PID 1, via
sd_pid_notify_with_fds() which PID 1 will store individually for each
service, and pass via the usual fd passing logic on next invocation.
This is useful for enable daemon reload schemes where daemons serialize
their state to /run, push their fds into PID 1 and terminate, restoring
their state on next start from the data in /run and passed in from PID
1.
The fds are kept by PID 1 as long as no POLLHUP or POLLERR is seen on
them, and the service they belong to are either not dead or failed, or
have a job queued.
|
|
it's not quite as destructive as it sounds nowadays
|
|
Option was being parsed but not used for anything.
|
|
Using:
find . -name '*.[ch]' | xargs sed -r -i -e \
's/log_unit_(debug|info|notice|warning|error|emergency)\(([^"]+), "(.*)%s"(.*), strerror\(-([a-zA-Z_]+)\)\);/log_unit_\1_errno(\2, \5, "\3%m"\4);/'
|
|
Also, while we are at it, introduce some syntactic sugar for creating
ERRNO= and MESSAGE= structured logging fields.
|
|
- Rename log_meta() → log_internal(), to follow naming scheme of most
other log functions that are usually invoked through macros, but never
directly.
- Rename log_info_object() to log_object_info(), simply because the
object should be before any other parameters, to follow OO-style
programming style.
|
|
subhierarchies
For priviliged units this resource control property ensures that the
processes have all controllers systemd manages enabled.
For unpriviliged services (those with User= set) this ensures that
access rights to the service cgroup is granted to the user in question,
to create further subgroups. Note that this only applies to the
name=systemd hierarchy though, as access to other controllers is not
safe for unpriviliged processes.
Delegate=yes should be set for container scopes where a systemd instance
inside the container shall manage the hierarchies below its own cgroup
and have access to all controllers.
Delegate=yes should also be set for user@.service, so that systemd
--user can run, controlling its own cgroup tree.
This commit changes machined, systemd-nspawn@.service and user@.service
to set this boolean, in order to ensure that container management will
just work, and the user systemd instance can run fine.
|
|
|
|
if sigabrt doesn't do the job, follow regular shutdown
routine, sigterm > sigkill.
|
|
sd_bus_get_peer_creds()
Clean up the function namespace by renaming the following:
sd_bus_get_owner_uid() → sd_bus_get_name_creds_uid()
sd_bus_get_owner_machine_id() → sd_bus_get_name_machine_id()
sd_bus_get_peer_creds() → sd_bus_get_owner_creds()
|
|
|
|
SERVICE_STOP would mean we're running the ExecStop command. That's not
the case with "STOPPING=1".
Instead we should enter the same state as if we just told the service
to stop, i.e. SERVICE_STOP_SIGTERM.
This fixes a bug where voluntarily exiting services would hang around in
deactivating state until timeout.
|
|
This makes possible to spawn service instances triggered by socket with
MLS/MCS SELinux labels which are created based on information provided by
connected peer.
Implementation of label_get_child_mls_label derived from xinetd.
Reviewed-by: Paul Moore <pmoore@redhat.com>
|
|
If BusPolicy= was passed, the parser function will have created
an ExecContext->bus_endpoint object, along with policy information.
In that case, create a kdbus endpoint, and pass its path name to the
namespace logic, to it will be mounted over the actual 'bus' node.
At endpoint creation time, no policy is updloaded. That is done after
fork(), through a separate call. This is necessary because we don't
know the real uid of the process earlier than that.
|
|
This way, the list of arguments to that function gets more comprehensive,
and we can get around passing lots of NULL and 0 arguments from socket.c,
swap.c and mount.c.
It also allows for splitting up the code in exec_spawn().
While at it, make ExecContext const in execute.c.
|
|
When this system-wide start-up timeout is hit we execute one of the
failure actions already implemented for services that fail.
This should not only be useful on embedded devices, but also on laptops
which have the power-button reachable when the lid is closed. This
devices, when in a backpack might get powered on by accident due to the
easily reachable power button. We want to make sure that the system
turns itself off if it starts up due this after a while.
When the system manages to fully start-up logind will suspend the
machine by default if the lid is closed. However, in some cases we don't
even get as far as logind, and the boot hangs much earlier, for example
because we ask for a LUKS password that nobody ever enters.
Yeah, this is a real-life problem on my Yoga 13, which has one of those
easily accessible power buttons, even if the device is closed.
|
|
This is useful for services that simply want to run something on
shutdown, but not at bootup. They should only set ExecStop= but leave
ExecStart= unset.
|
|
|
|
and STOPPING=1 sd_notify() messages
|
|
Unlike strv_find_prefix() the new call will return a pointer to the
suffix of the item we found, instead of the whole item. This is more
closer inline with what startswith() does, and allows us to simplify a
couple of invocations.
|
|
|
|
|
|
need to duplicate that
|
|
|
|
|
|
We shouldn't show status texts from previous service starts
|
|
|
|
|
|
StatusErrno dbus property along StatusText to allow notification of numeric status condition while degraded service operation or any other special situation.
|
|
|
|
We should follow the naming scheme waitid() uses, not come up with our
own reversed one...
|
|
This does the inverse of RestartPreventExitStatus=: it forces a restart
of a service when a certain exit status is returned by a service
process.
|
|
Parsing sysv files was moved to the sysv-generator in the previous commit.
This patch removes the sysv parsing from serivce.c.
Note that this patch drops the following now unused sysv-specific info
from service dump:
"SysV Init Script has LSB Header: (yes/no)"
"SysVEnabled: (yes/no)"
"SysVRunLevels: (levels)"
|
|
Restart=on-abnormal is similar to Restart=on-failure, but avoids
restarts on unclean exit codes (but still doing restarts on all
obviously unclean exits, such as timeouts, signals, coredumps, watchdog
timeouts).
Also see:
https://fedorahosted.org/fpc/ticket/191
|