Age | Commit message (Collapse) | Author |
|
Allows using journal.send('msg', PRIORITY=journal.LOG_CRIT)
Before this commit this results in
TypeError: cannot concatenate 'str' and 'int' objects
and requires passing PRIORITY value as string to work.
|
|
|
|
https://bugzilla.redhat.com/show_bug.cgi?id=995575
|
|
src/python-systemd/_reader.c: In function Reader_get_catalog:
src/python-systemd/_reader.c:912:53: warning: comparison between signed and unsigned integer expressions [-Wsign-compare]
assert(mid_len > l);
^
|
|
|
|
sphinx, oh sphinx, why do you require manual ficksups all the time?
|
|
Also export missing flags.
|
|
Back in 6a58bf4135 raising stop iteration was removed from the C
code, but wasn't added in the Python counterpart.
|
|
_listen_fds() is modified to accept unset_environment arg as keyword,
to match new notify().
|
|
This is the just the library part.
SD_JOURNAL_CURRENT_USER flags is added to sd_j_open(), to open
files from current user.
SD_JOURNAL_SYSTEM_ONLY is renamed to SD_JOURNAL_SYSTEM,
and changed to mean to (also) open system files. This way various
flags can be combined, which gives them nicer semantics, especially
if other ones are added later.
Backwards compatibility is kept, because SD_JOURNAL_SYSTEM_ONLY
is equivalent to SD_JOURNAL_SYSTEM if used alone, and before there
we no other flags.
|
|
Bug-spotted-by: Steven Hiscocks <steven-systemd@hiscocks.me.uk>
|
|
flush() is potentially costly.
|
|
|
|
|
|
sd_get_uids, sd_get_seats, sd_get_sessions, and sd_get_machine_names.
|
|
|
|
|
|
Arbitrary fields can be attached at the level of the handler,
and they'll be sent with all messages from this handler.
This facility is used to attach SYSLOG_IDENTIFIER to all messages,
since otherwise journald attaches SYSLOG_IDENTIFIER=python or
something similar, which is completely useless.
|
|
|
|
http://lists.freedesktop.org/archives/systemd-devel/2013-April/010510.html
|
|
|
|
The information about the unit for which files are being parsed
is passed all the way down. This way messages land in the journal
with proper UNIT=... or USER_UNIT=... attribution.
'systemctl status' and 'journalctl -u' not displaying those messages
has been a source of confusion for users, since the journal entry for
a misspelt setting was often logged quite a bit earlier than the
failure to start a unit.
Based-on-a-patch-by: Oleksii Shevchuk <alxchk@gmail.com>
|
|
Changes to _Reader make it match closer to C API, by removing `get_next`
and `get_previous`. A `get_all` method added, which returns dictionary
of fields using C API SD_JOURNAL_FOREACH_DATA macro, which can be used
in conjunction with `next`.
_Reader `get`, `next`, `get_{realtime,monotonic,cursor}` and new
`previous` methods are made private. This is so the traversal and
getting of journal fields can be made transparent in the python
interface.
Reader now solely implements `get_next` and `get_previous`, returning a
standard dictionary (future: other mapping types?) with all standard and
special fields through the converters. This makes the output the same as
journalctl json/export format output.
Iterator methods also moved to Reader, as they do not function as intend
with changes to _Reader.
These changes also mean that more optimised journal interfaces can be
made more easily from _Reader, by avoiding getting of unrequired fields
by using the `_get` method, and avoiding field conversions.
|
|
get_timeout_ms is added as a convenience function, since
it is abysmally hard to call clock_gettime() in Python
versions lower than 3.3. And even for Python 3.3 users
it saves a few lines.
|
|
|
|
|
|
Before, we would initialize many fields twice: first
by filling the structure with zeros, and then a second
time with the real values. We can let the compiler do
the job for us, avoiding one copy.
A downside of this patch is that text gets slightly
bigger. This is because all zero() calls are effectively
inlined:
$ size build/.libs/systemd
text data bss dec hex filename
before 897737 107300 2560 1007597 f5fed build/.libs/systemd
after 897873 107300 2560 1007733 f6075 build/.libs/systemd
… actually less than 1‰.
A few asserts that the parameter is not null had to be removed. I
don't think this changes much, because first, it is quite unlikely
for the assert to fail, and second, an immediate SEGV is almost as
good as an assert.
|
|
This can give huge efficiency gains, e.g. if only MESSAGE
is required and all other fields can be ignored.
|
|
This matches the C API more closely, and also enables the
user to get just partial information, should she desire to
do so.
Functions names in error messages are modified to not include
the class name, because Python uses just the function name
into functions declared as METH_NOARGS, and error messages
were inconsistent.
|
|
Getting the cursor is split out from .get_next() into
.get_cursor(). This mirrors the C API more closely, and
also makes things a bit faster if the cursor is not needed.
|
|
The behaviour wrt. seconds vs. microseconds was inconsistent.
Now _Reader always uses native units (us), while Reader always
uses seconds and accepts both floats and ints. This way the
conversion is always done in the Python layer, and the lower
level API allows access to the journal API without the potentially
lossy conversion between double and uint64_t.
|
|
|
|
|
|
- separate methods with two empty lines for clarity
- avoid malloc(0) by specyfing private data size as -1
- add method name in error messages
|
|
This one wraps sd_journal_get_catalog_from_message_id.
Thanks to Python namespacing, we can stick to a shorter name.
|
|
This one wraps sd_journaal_get_catalog.
|
|
This should make the file interface of _Reader complete.
|
|
|
|
Please see the documentation (e.g. pydoc3 systemd.daemon) for full
description. As usual, systemd._daemon wraps the raw interface, while
systemd.daemon provides the more pythonic API. sd_listen_fds,
sd_booted, sd_is_fifo, sd_is_socket, sd_is_socket_unix,
sd_is_socket_inet, sd_is_mq, and SD_LISTEN_FDS_START are currently
wrapped.
|
|
This should help readers of the man or HTML pages know if the documentation
is out of date. An alternative to use a date generated from 'git log' was
considered, but since we try to keep user visible documentation up to date,
showing the project version should be enough.
|
|
I forgot to commit the layout file, because it was gitignored.
Fixed now.
|
|
The result is ugly enough, I hope, to motivate someone with
design skills to fix it.
|
|
|
|
|
|
|
|
|
|
It's better to explictly check, instead of just documenting it.
The return value from init is changed from 1 to -1 on error.
Python seems to ignore 1 every second time. Looks like a bug
in Python, but the return value doesn't seem to be documented
anywhere, and -1 works as expected... so let's just use that.
|
|
sd_journal_get_fd(j) is called j.fileno(), for compatiblity with
Python conventions for file-like objects.
More importantly, those new .seek_head() and .seek_tail() do not
call .get_next(). This is better, if one wants to skip before
retrieving an entry.
|
|
This way python code follows the original interface more closely.
Also, .seek(0, journal.SEEK_END) was just to much to type.
|
|
First of all, 'try: ... except: ...' (with no exception specified) is
always a no-no, since it catches all BaseExceptions, which includes ^C
and other stuff which should almost never be caught.
Now the conversion is stricter, and only one conversion is attempted,
and only a ValueEror is caught. It seems reasonable to catch ValueErrors,
since the entries in the journal are not verified, and any erroneous
application might log a field which cannot be converted. The consumer
of events must only check if a field is an instance of bytes and can
otherwise assume that the conversion was performed correctly.
Order of arguments in Reader.__init__ has been changed to match order
in _Reader.__init__.
Conversions have been updated to work under Python 2 and 3.
|