authorLennart Poettering <lennart@poettering.net>2017-02-06 13:49:44 +0100
committerLennart Poettering <lennart@poettering.net>2017-02-06 18:21:27 +0100
commitb3bb64767abacc5b759255a698c89b3495cd54f4 (patch)
tree2cb580ed47c8ef2542dfedfb08f26fcb6ec06151
parent3576dddf2768a362f67a0df063c459df05b9c343 (diff)
man: document that sd_notify() is racy in some cases
-rw-r--r--man/sd_notify.xml9
-rw-r--r--man/systemd-notify.xml15
-rw-r--r--man/systemd.service.xml40
3 files changed, 40 insertions, 24 deletions
diff --git a/man/sd_notify.xml b/man/sd_notify.xml
index 6e98041912..4dcefc4baf 100644
--- a/man/sd_notify.xml
+++ b/man/sd_notify.xml
@@ -268,6 +268,15 @@
<citerefentry><refentrytitle>systemd.service</refentrytitle><manvolnum>5</manvolnum></citerefentry>
for details.</para>
+ <para>Note that <function>sd_notify()</function> notifications may be attributed to units correctly only if either
+ the sending process is still around at the time PID 1 processes the message, or if the sending process is
+ explicitly runtime-tracked by the service manager. The latter is the case if the service manager originally forked
+ off the process, i.e. on all processes that match <varname>NotifyAccess=</varname><option>main</option> or
+ <varname>NotifyAccess=</varname><option>exec</option>. Conversely, if an auxiliary process of the unit sends an
+ <function>sd_notify()</function> message and immediately exits, the service manager might not be able to properly
+ attribute the message to the unit, and thus will ignore it, even if
+ <varname>NotifyAccess=</varname><option>all</option> is set for it.</para>
+
<para><function>sd_notifyf()</function> is similar to
<function>sd_notify()</function> but takes a
<function>printf()</function>-like format string plus
diff --git a/man/systemd-notify.xml b/man/systemd-notify.xml
index 4a8e119eb6..9bb35a3a0c 100644
--- a/man/systemd-notify.xml
+++ b/man/systemd-notify.xml
@@ -72,10 +72,17 @@
<para>The command line may carry a list of environment variables
to send as part of the status update.</para>
- <para>Note that systemd will refuse reception of status updates
- from this command unless <varname>NotifyAccess=all</varname> is
- set for the service unit this command is called from.</para>
-
+ <para>Note that systemd will refuse reception of status updates from this command unless
+ <varname>NotifyAccess=</varname> is set for the service unit this command is called from.</para>
+
+ <para>Note that <function>sd_notify()</function> notifications may be attributed to units correctly only if either
+ the sending process is still around at the time PID 1 processes the message, or if the sending process is
+ explicitly runtime-tracked by the service manager. The latter is the case if the service manager originally forked
+ off the process, i.e. on all processes that match <varname>NotifyAccess=</varname><option>main</option> or
+ <varname>NotifyAccess=</varname><option>exec</option>. Conversely, if an auxiliary process of the unit sends an
+ <function>sd_notify()</function> message and immediately exits, the service manager might not be able to properly
+ attribute the message to the unit, and thus will ignore it, even if
+ <varname>NotifyAccess=</varname><option>all</option> is set for it.</para>
</refsect1>
<refsect1>
diff --git a/man/systemd.service.xml b/man/systemd.service.xml
index 522ed5e61e..420ae4e7b5 100644
--- a/man/systemd.service.xml
+++ b/man/systemd.service.xml
@@ -792,26 +792,26 @@
<varlistentry>
<term><varname>NotifyAccess=</varname></term>
- <listitem><para>Controls access to the service status
- notification socket, as accessible via the
- <citerefentry><refentrytitle>sd_notify</refentrytitle><manvolnum>3</manvolnum></citerefentry>
- call. Takes one of <option>none</option> (the default),
- <option>main</option>, <option>exec</option> or
- <option>all</option>. If <option>none</option>, no daemon status
- updates are accepted from the service processes, all status
- update messages are ignored. If <option>main</option>, only
- service updates sent from the main process of the service are
- accepted. If <option>exec</option>, only service updates sent
- from any of the control processes originating from one of the
- <varname>Exec*=</varname> commands are accepted. If
- <option>all</option>, all services updates from all members of
- the service's control group are accepted. This option should
- be set to open access to the notification socket when using
- <varname>Type=notify</varname> or
- <varname>WatchdogSec=</varname> (see above). If those options
- are used but <varname>NotifyAccess=</varname> is not
- configured, it will be implicitly set to
- <option>main</option>.</para></listitem>
+ <listitem><para>Controls access to the service status notification socket, as accessible via the
+ <citerefentry><refentrytitle>sd_notify</refentrytitle><manvolnum>3</manvolnum></citerefentry> call. Takes one
+ of <option>none</option> (the default), <option>main</option>, <option>exec</option> or
+ <option>all</option>. If <option>none</option>, no daemon status updates are accepted from the service
+ processes, all status update messages are ignored. If <option>main</option>, only service updates sent from the
+ main process of the service are accepted. If <option>exec</option>, only service updates sent from any of the
+ main or control processes originating from one of the <varname>Exec*=</varname> commands are accepted. If
+ <option>all</option>, all services updates from all members of the service's control group are accepted. This
+ option should be set to open access to the notification socket when using <varname>Type=notify</varname> or
+ <varname>WatchdogSec=</varname> (see above). If those options are used but <varname>NotifyAccess=</varname> is
+ not configured, it will be implicitly set to <option>main</option>.</para>
+
+ <para>Note that <function>sd_notify()</function> notifications may be attributed to units correctly only if
+ either the sending process is still around at the time PID 1 processes the message, or if the sending process
+ is explicitly runtime-tracked by the service manager. The latter is the case if the service manager originally
+ forked off the process, i.e. on all processes that match <option>main</option> or
+ <option>exec</option>. Conversely, if an auxiliary process of the unit sends an
+ <function>sd_notify()</function> message and immediately exits, the service manager might not be able to
+ properly attribute the message to the unit, and thus will ignore it, even if
+ <varname>NotifyAccess=</varname><option>all</option> is set for it.</para></listitem>
</varlistentry>
<varlistentry>